Part 2: Concept Design 2 - 69 where the wall finish m eets the ceiling, and sealant where the floor treatm ent meets the wall finish. Figure 6.2 Typical floor treatment to provide improved acoustic performance 1 2 5 3 4 6 1 Dense mineral wool 2 Acoustic sealant 3 Mineral wool packing 4 Precast concrete unit 5 Floor treatment 6 Sealant Figure 6.3 Typical flanking detail for an internal separating wall Separating walls between occupancies are likely to be of double skin construction to reduce noise transmission, facilitating the use of bracing within the wall construction.